Mindray BC-7600 Series Auto Hematology Analyzer
Mindray BC-7600 Series auto hematology analyzer with an integrated ESR module - CBC and ESR results from one tube in a single test.
ICEN supplies selected professional medical equipment. Product availability and market authorization vary by country.
CBC and ESR from one tube, without a separate ESR analyzer
The Mindray BC-7600 Series is an automated hematology analyzer with an integrated ESR module, so a CBC and an ESR result are produced from one tube in a single test. ESR is measured by a photometric method that Mindray specifies at 40 seconds or less, against a Westergren reference of 3600 seconds or more and a correlation of r=0.94. Removing the separate ESR analyzer removes a second sample and a second workflow step.
The 5-part differential uses SF Cube technology - scatter, fluorescence and 3D cube analysis with a laser source - and was designed to give sensitive alerts for abnormal cells such as blasts and abnormal lymphocytes. The series covers the BC-7600, BC-7800 and BC-7900, with reportable parameters from 54 upward and 59 or more research parameters depending on model.
Throughput reaches up to 110 samples per hour for CBC and CD, and up to 90 samples per hour for ESR and CBC+ESR. Whole-blood sampling uses 85 uL for CBC, CD, Ret, CDR and CDR/PLT-8X, or 140 uL for ESR and CBC+ESR, with a 27 +/- 2 uL micro whole-blood mode. The autoloader holds up to 50 tubes. Platelet counting uses PLT-H dual-scattergram fusion with an 8x recount and clump de-aggregation. ICEN supplies the BC-7600 Series to hospital laboratories, diagnostic centres and distributors, and confirms the exact model, configuration and destination-market requirements before quotation.
Applications
- Clinical laboratories
- Combined CBC and ESR workflows
- Abnormal-cell flagging and reflex testing
- High-throughput laboratory workload
Who is this product for?
- Laboratories running CBC and ESR on separate instruments
- Medium and large clinical laboratories
- Sites needing reflex and auto-retest workflows
- Distributors supplying premium 5-part analyzers
Selected Product Highlights
Specifications below are presented from the current ICEN product catalog. Confirm final configuration and technical documents with our team before purchase.
CBC and ESR from one tube in a single test - integrated ESR module
Photometric ESR, specified at 40 seconds or less
SF Cube 5-part differential with sensitive abnormal-cell alerts
Up to 110 samples per hour (CBC, CD); up to 90 samples per hour with ESR
PLT-H dual-scattergram fusion with 8x recount and clump de-aggregation
Series covers BC-7600, BC-7800 and BC-7900; 50-tube autoloader
Mindray BC-7600 Series Auto Hematology Analyzer - key specifications
| Brand | Mindray |
|---|---|
| Model | BC-7600 Series (BC-7600 / BC-7800 / BC-7900) |
| Category | 5-part auto hematology analyzer with integrated ESR |
| Test scope | CBC, WBC differential, ESR and combined CBC+ESR panels |
| Parameters reported | 54 reportable parameters listed for the series: WBC, Bas#, Bas%, Neu#, Neu%, Eos#, Eos%, Lym#, Lym%, Mon#, Mon%, IMG#, IMG%, Neu-X, Neu-Y, Mon-X, RBC, HGB, MCV, MCH, MCHC, RDW-CV, RDW-SD, HCT, NRBC#, NRBC%, Micro%, Macro%, PLT, MPV, PDW, PCT, P-LCR, P-LCC, PLT-H, PLT-I, ESR; RET%, RET#, RHE, IRF, LFR, MFR, HFR, MCVr, DELTA-CH, MCHr, HDW, MCHm, HYPO-CH%, HYPER-CH% and IPF, IPF#, PLT-O are BC-7800 only |
| Research parameters | Whole blood: BC-7600 has 59 research parameters, BC-7800 has 77, BC-7900 has 60. Body fluid: 30 research parameters for BC-7800, 11 for BC-7600 and BC-7900 |
| Histograms | 3 histograms: RBC, PLT and PLT-H |
| ESR method | Photometric method for the ESR test, provided by an automatic ESR module integrated in the analyzer (Mindray 'Easy-W' ESR); result within 40 s versus >= 3600 s for the traditional Westergren method, with correlation to Westergren reported as r = 0.94 |
| ESR workflow | CBC/CD/CDR and ESR results from one tube in a single test - brochure states within 1 min; the mindray.com product page states CBC & ESR results in one test within 40 seconds |
| ESR accuracy / QC | Uses the same QC and calibrator as the BC-6800Plus Series; combined examination helps avoid the interferences of dehydration, polycythemia vera and anemia on ESR results; compared with the Westergren method the ESR method performs better in quality traceability, repeatability, speed, safety and level of automation |
| Throughput | Up to 110 samples per hour (CBC, CD); up to 90 samples per hour (ESR, CBC+ESR, CD+ESR); up to 65 samples per hour (Ret, CDR, CDR+ESR); up to 65 samples per hour (CD+HMC); up to 35 samples per hour (CDR/PLT-8X, PLT-O, CD/PLT-O) |
| Sample volume | 85 uL for CBC, CD, Ret, CDR, CDR/PLT-8X, CD/PLT-O; 140 uL for ESR, CBC+ESR, CD+ESR, CDR+ESR, CD+HMC |
| Sample volume (micro) | 27 +/- 2 uL for CBC, CD; 36.5 +/- 2 uL for Ret, CDR, CDR/PLT-8X, PLT-O, CD/PLT-O; 50 uL for CD+HMC; 90 uL for ESR, CD+ESR, CDR+ESR |
| Sample handling | Autoloader included; loading capacity up to 50 sample tubes; sample types whole blood, micro whole blood, predilute and body fluid |
| Differential | SF Cube technology (Scatter, Fluorescence, Cube 3D analysis) using a laser source with side laser scatter (cellular complexity), fluorescence signals (DNA/RNA information) and forward laser scatter (cell size); 5-part WBC differential in the DIFF channel plus a WNB channel for Basophil and NRBC results without additional reagents |
| Platelet counting | PLT-H dual-scattergram fusion (optical PLT-H in every CD test, combining small PLTs from the impedance method and large PLTs from the optical method), PLT-I, and PLT-O with automatic 8-times statistical analysis on low PLT count samples (no re-aspiration) and automated PLT-clump de-aggregation/resolution of EDTA-induced pseudo-thrombocytopenia |
| Abnormal cell flagging | Coordinated DIFF + WNB analysis gives sensitive alerts for 'Blasts', 'Abn. Lymph/blast?' and 'Abn. Promyelocyte/blast?'; detection concentration as low as 0.03 x 10^9/L; HMC scattergram (BC-7900) improves specificity for hematological malignant cells by approximately 40% compared with CD mode; reactive lymphocytosis caused by infectious mononucleosis flagged as 'Reactive Lymph-IM?' (sensitivity 73.2%, specificity 96.56%) |
| Reagents | Cyanide-free reagent for the hemoglobin test; WNB (Basophil and NRBC) results and optical PLT-H require no additional reagents |
| Data storage | BC-7600: up to 130,000 results including numeric and graphical information; BC-7800 and BC-7900: up to 140,000 results |
| Power | Power voltage 100 V-240 V (~, +/-10%); input power 500 VA; frequency 50 Hz/60 Hz (+/-1 Hz) |
| Dimensions | Width <= 675 mm, height <= 850 mm, depth <= 870 mm |
| Weight | <= 150 kg (autoloader included) |
If you are comparing 5-part analyzers, our buying guide sets out the selection criteria; the models below cover different throughput levels and sample volumes.
Common questions about Mindray BC-7600 Series Auto Hematology Analyzer
Does the BC-7600 Series measure ESR on the same instrument?
Yes. An integrated ESR module reports ESR alongside the CBC, so CBC and ESR results come from one tube in a single test.
How fast is the ESR measurement?
Mindray specifies the photometric ESR method at 40 seconds or less, against a Westergren reference of 3600 seconds or more, with a correlation of r=0.94.
What is the throughput of the BC-7600 Series?
Up to 110 samples per hour for CBC and CD, and up to 90 samples per hour for ESR and CBC+ESR.
How much blood does it need?
85 uL for CBC, CD, Ret, CDR and CDR/PLT-8X, or 140 uL for ESR and CBC+ESR. A micro whole-blood mode uses 27 +/- 2 uL for CBC and CD.
Which models are in the series?
The series covers the BC-7600, BC-7800 and BC-7900. Reportable and research parameter counts and storage capacity differ by model - confirm which variant suits your workload with ICEN.
Can ICEN provide a quotation?
Yes. Send the estimated quantity, destination market and required configuration through the Request a Quote button.
Related products and resources
Need a quotation or product configuration?
Send the model, estimated quantity, destination market and required configuration - our export team will reply with availability, documentation and pricing.