Mindray BC-5380 Automated Hematology Analyzer
Hematology Analyzer

Mindray BC-5380 Automated Hematology Analyzer

Mindray BC-5380 automated hematology analyzer with a 5-part differential, 20 uL whole-blood sampling and up to 60 samples per hour for small and medium laboratories.

Brand: Mindray · Model: Mindray BC-5380
ICEN supplies selected professional medical equipment. Product availability and market authorization vary by country.
Product Overview

A 5-part analyzer for small and medium laboratory workload

The Mindray BC-5380 is an automated hematology analyzer that reports a complete blood count and a 5-part white blood cell differential - 27 parameters in total, including LIC and ALY. A CBC+DIFF report is produced from 20 uL of whole blood in about one minute, and a CBC-only test needs 15 uL, which keeps the analyzer usable for pediatric and difficult-draw patients.

Throughput is specified at up to 60 samples per hour with the autoloader and up to 50 samples per hour in closed-tube mode. The 30-tube autoloader supports random access for continuous loading, and an independent closed-tube and capillary compartment lets STAT and capillary samples be run without interrupting the routine queue.

The differential uses flow cytometry with semi-conductor laser scatter for forward and side scatter, combined with a patented cluster algorithm. Windows-based software covers customizable reference ranges and report styles, automatic cleaning, and day-to-day quality control with 60 QC files and 4 QC programs. HL7 is supported with uni- and bi-directional LIS connection. ICEN supplies the BC-5380 to hospital laboratories, diagnostic centres and distributors, and confirms configuration, reagent and service requirements before quotation.

Applications

  • Clinical laboratories
  • Routine CBC and 5-part differential testing
  • STAT and capillary samples alongside routine queues
  • Laboratories with day-to-day QC requirements

Who is this product for?

  • Small and medium clinical laboratories
  • Laboratories needing STAT and capillary handling
  • Sites standardising on a Windows-based LIS workflow
  • Distributors supplying 5-part analyzers
Key Features

Selected Product Highlights

Specifications below are presented from the current ICEN product catalog. Confirm final configuration and technical documents with our team before purchase.

01

CBC + 5-part differential with 27 parameters including LIC and ALY

02

20 uL whole blood for a CBC+DIFF report in about one minute

03

Up to 60 samples per hour with autoloader

04

30-tube autoloader plus an independent closed-tube and capillary compartment

05

Semi-conductor laser scatter with a patented cluster algorithm

06

Day-to-day QC: 60 QC files, 4 QC programs; uni- and bi-directional LIS

Technical Specifications

Mindray BC-5380 Automated Hematology Analyzer - key specifications

BrandMindray
ModelBC-5380
Category5-part hematology analyzer
Test scopeCBC and CBC+DIFF (5-part WBC differential); supports whole blood and capillary blood samples
Parameters reported27 parameters: WBC, Lym%, Mon%, Neu%, Eos%, Bas%, Lym#, Mon#, Neu#, Eos#, Bas#, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, LIC%, LIC#, ALY%, ALY#; 3 histograms and 1 scattergram
ThroughputUp to 60 samples per hour with autoloader; up to 50 samples per hour in closed tube mode
Sample volumeWhole blood 20 uL; prediluted 20 uL; 20 uL for CBC+DIFF and 15 uL for CBC tests; a five-part report is obtained in about 1 minute
Sample handling30-tube autoloader with random access for continuous loading; independent closed tube compartment for STAT and capillary samples; supports selected microtainer tubes
Differential methodFlow cytometry (FCM) with semi-conductor laser scatter (forward and side scatter) + chemical dye method; independent basophil channel measured by impedance
Platelet countingAdvanced impedance measurement for RBC and PLT (Mindray patented digital sheath flow and weak signal detection, dynamic discriminator adjustment); PLT linearity 0-1000 x10^9/L; precision <= 4.0% (150-500 x10^9/L); carryover <= 1.0%
ReagentsFour routine M-53 reagents used in the counting cycle with 2 years shelf life; three levels of BC-5D controls offered as a ready-to-use kit (assay value table imported via USB memory)
Data storageUp to 40,000 patient results including numeric and graphical information; 60 QC files
LIS / connectivitySupports HL7 protocol; uni- and bi-directional LIS connection (orders/patient info downloaded, results transmitted automatically); LAN port
QC60 QC files store Levey-Jennings (L-J) QC results, 300 data points per file, 4 common QC programs enabled; day-to-day QC monitoring
PerformanceWBC precision <= 2.0% (4-15 x10^9/L), carryover <= 0.5%; RBC precision <= 1.5% (3.5-6.0 x10^12/L), carryover <= 0.5%; HGB precision <= 1.5% (110-180 g/L), carryover <= 0.5%; PLT precision <= 4.0% (150-500 x10^9/L), carryover <= 1.0%; linearity WBC 0.00-99.99 x10^9/L, RBC 0.00-8.00 x10^12/L, HGB 0-250 g/L, PLT 0-1000 x10^9/L
SoftwareWindows-based software; customizable reference range, report styles and auto-cleaning schedule; report format tool can add microscopic counting, ESR, blood type and diagnostic remarks; compact and no external air pump
Weight<= 58 kg
Hematology & laboratory scope

If you are comparing 5-part analyzers, our buying guide sets out the selection criteria; the models below cover different throughput levels and sample volumes.

FAQ

Common questions about Mindray BC-5380 Automated Hematology Analyzer

What does the BC-5380 report?

A complete blood count with a 5-part WBC differential - 27 parameters including LIC and ALY.

How much blood does the BC-5380 need?

20 uL of whole blood for a CBC+DIFF report, or 15 uL for a CBC-only test. 20 uL is also used in prediluted mode.

How fast is the BC-5380?

A CBC+DIFF report takes about one minute. Throughput is up to 60 samples per hour with the autoloader and up to 50 samples per hour in closed-tube mode.

Can STAT and capillary samples be run without stopping the routine queue?

Yes. The 30-tube autoloader supports random access, and there is an independent closed-tube and capillary compartment for STAT samples.

Does the BC-5380 support quality control?

Yes. It stores 60 QC files with 300 data points per file and supports 4 QC programs, and HL7 with uni- and bi-directional LIS is available.

Can ICEN provide a quotation?

Yes. Send the estimated quantity, destination market and required configuration through the Request a Quote button.

Need a quotation or product configuration?

Send the model, estimated quantity, destination market and required configuration - our export team will reply with availability, documentation and pricing.